Important rules while preparing Bar Bending Schedule

The bars used in building should be grouped together for each structural unit and listed separately for each floor.

Bars are listed in numerical order.

To identify the bar in the bundle of bars, each bar is uniquely labelled with reference details (Length of the bar, size of the bar, Shape of the bar).

The type of bar and shape of the bar should be in accordance with B8666.

It is essential that the bar mark reference on the label attached to a bundle of bars refers uniquely to a particular group or set of bars of defined length, size, shape and type used on the job.

The cutting length and bending length calculations are separately calculated and not included in the detailed list. Like I have listed the Bar Bending details in a table and calculations are done separately.